ATC150
Adjustment method:2P-type(which can set different return information)
Input signal:PTC Thermal resistance
Accuracy:1.0
Output:Relay(3A,250V)
Power output:DC24V
Operating voltage:AC110/220V
Dimensions:35×76×70
Hole Size:30×71mm
Red RectangleDetailed Datasheet    Red RectanglePDF Datasheet    Red RectangleInquiry of
 
 
 
 
NO
 
NO
 
NO
 
NO
 
NO
 
NO
 
NO
 
ATC90 Sire
Input signal: A product compatible with thermocouple, RTD, current and voltage specifications 21
Output control:Four specifications of optional, conventional products with two outputs (except for 48 * 48 series)
Alarm function:Up to two output, 12 modes
Degrees or Fahrenheit switchable      Accuracy: 0.5% FS 
Power supply: 86-265V AC, 24VAC/DC
Dimensions: choice of five standard dimensions
Red RectangleDetailed Datasheet    Red RectanglePDF Datasheet    Red RectangleInquiry of
 
 
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
 
ATC01
Input signal: K, J, E, S thermocouple   
Output control: time proportion adjustment style ect 
                          relay, ssr relay, voltage output.
Power source: AC110V. 220V. 380V 50Hz/60Hz
Alarm function: no alarm
Measuring range: 0~200℃ , 0~400℃         Accuracy: class 1.0  
Outline size: 96×96×122(mm)    Opening size : 92+1×92+1 (mm)
Red RectangleDetailed Datasheet    Red RectanglePDF Datasheet    Red RectangleInquiry of
 
 
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
 
ATC02
Input signal: K, J, E, S thermocouple 
Output control: time proportion adjustment style ect 
                          relay, ssr relay, voltage output.
Power source: AC110V. 220V. 380V 50Hz/60Hz
Alarm function: no alarm 
Measuring range: 0~200℃,0~400℃         Accuracy: class 0.5/1.0   
 Outline size: 96×96×100(mm)    Opening size : 92+1×92+1 (mm)
Red RectangleDetailed Datasheet    Red RectanglePDF Datasheet    Red RectangleInquiry of
 
 
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
 
ATC03
Input signal: K, J, E, S thermocouple 
Output control: time proportion adjustment style ect 
                          relay, ssr relay, voltage output.
Power source: AC110V. 220V. 380V 50Hz/60Hz
Alarm function: no alarm 
Measuring range: 0~200℃,0~400℃         Accuracy: class 1.5   
Outline size: 96×96×122(mm)    Opening size : 92+1×92+1 (mm)
Red RectangleDetailed Datasheet    Red RectanglePDF Datasheet    Red RectangleInquiry of
 
 
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
 
ATC04
Input signal: K, J, E, S thermocouple 
Output control: time proportion adjustment style ect 
                          relay, ssr relay, voltage output.
Power source: AC110V. 220V. 380V 50Hz/60Hz
Alarm function: no alarm 
Measuring range: 0~999℃         Accuracy: class 1.5  
Outline size: 48×48×110(mm)    Opening size : 45+1×45+1 (mm)
Red RectangleDetailed Datasheet    Red RectanglePDF Datasheet    Red RectangleInquiry of
 
 
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
 
ATC05
Input signal: K, J, E, S thermocouple 
Output control: time proportion adjustment style ect
                          relay, ssr relay, voltage output.
Power source: AC110V. 220V. 380V 50Hz/60Hz
Alarm function: no alarm
Measuring range: 0~999℃         Accuracy: class 1.0  
Outline size: 48×96×110(mm)    Opening size :45+1×92+1 (mm)
Red RectangleDetailed Datasheet    Red RectanglePDF Datasheet    Red RectangleInquiry of
 
 
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
 
ATC06
Input signal: K, J, E, S thermocouple 
Output control: time proportion adjustment style ect 
                          relay, ssr relay, voltage output.
Power source: AC110V. 220V. 380V 50Hz/60Hz
Alarm function: no alarm 
Measuring range: 0~400℃         Accuracy: class 1.5   
Outline size: 96×96×122(mm)    Opening size : 92+1×92+1 (mm)
Red RectangleDetailed Datasheet    Red RectanglePDF Datasheet    Red RectangleInquiry of
 
 
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
 
ATC07
Input signal: K, J, E, S thermocouple 
Output control: time proportion adjustment style ect 
                          relay, ssr relay, voltage output.
Power source: AC110V. 220V. 380V 50Hz/60Hz
Alarm function: with alarm 
Measuring range: 0~400℃         Accuracy: class 1.0   
Outline size: 72×72×100(mm)    Opening size: 68+1×68+1 (mm)
Red RectangleDetailed Datasheet    Red RectanglePDF Datasheet    Red RectangleInquiry of
 
 
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
NO
 
NO
 
NO
 
ATC08
Input signal: thermocouple K, J, E, S, N, T, B, R, WRe,
 thermo resistor CU50, PT100, Cu100,BA2,BA1,G,  
linear signal: 0-5V, 1-5V, 0~10mA , 4~20mA,0~20mV,0~75mV,0~200mV,F  
Output control: intelligent PID adjustment, relay, ssr relay, voltage ,current output.
Power source: AC85 ~264V  AC185~240V  AC110V  AC380V  50Hz/60Hz
Alarm function: with alarm 
Measuring range: -199.9℃~+1800℃         Accuracy: class 0.5 / 0.2 
Outline size:72×72×105(mm)    Opening size : 68+1×68+1 (mm)
Red RectangleDetailed Datasheet    Red RectanglePDF Datasheet    Red RectangleInquiry of
 
 